Optional Fan Ducting Kit Installation - Regency Greenfire GF1500NG Owners & Installation Manual

Table of Contents

Advertisement

installation

Optional Fan Ducting Kit Installation

OPTIONAL FAN DUCTING KIT INSTALLATION
LISTINGS AND CODE
APPROVALS
This Fan Kit has been approved for use with
GF1500L.
NOTE: ENERGY LABEL RATINGS DO
NOT REFLECT INSTALL OF OPTIONAL
FAN KIT.
Check with your local building code agency before
you begin your installation to ensure compliance
with local codes, including the need for "permits"
and follow-up inspections. If any problems are
encountered regarding code approvals, or if you
wish clarification on any of the instructions con-
tained here, contact your local dealer.
Ceiling
Register
Wall
Register
Ceiling
Register
Wall
Register
Diagram 1: Guide for possible air duct runs and
locations. Keep duct length and number of bends
to a miniumum. Maximum duct length is 9.0m.
The Extension Kit contains a maximum of up to
4.5m. Please purchase the Fan Duct Extension
Kit to increase the 9.0m
Item No.
Description
No
1
240V Fan As-
7
sembly
2
Duct Flange-
Fan
3
Adapter Round
8
to Oval
4
Angle Bracket
9
5
Junction Box
10
6
Wall Adapter
Plate
NOTE: The fan kit (946-591) does not contain
any ducting. The optional extension duct kit (7
in the noted table) is 4.5 metres in length and
its part number is 946-596.
919-592a
46
|
Greenfire® GF1500L-2 Gas Fireplace
GENERAL INFORMATION
The Fan Kit increases the effectiveness of your
fireplace by dispersing warm air from the fireplace
to remote locations in the same room or other
rooms in your home.
Up to two kits may be installed on the fireplace.
Important Installation Notes
1. The appliance installation must conform with
local codes and installation codes.
2. The appliance when installed, must be electri-
cally grounded in accordance with local codes.
3. This kit is tested and safe when installed in accord-
ance with this installation manual. Please read
all instructions before starting installation and
follow all instructions carefully during installation.
4. Installation of this kit must be performed by a
qualified service technician.
5. The Fan Kit must be installed only as specified.
Any modifications of the kit or components will
void the warranty and may cause a fire hazard.
6. Plan the location of the fireplace and the warm air
Floor
Register
duct runs, see diagram 1 as a guide for possible
duct runs and locations.
Description
Aluminum Flex 4.5m
Duct Flange-Stove
Sidewall Grille
Connector Clamp
If you require more than 4.5m please purchase Fan
Duct Extension Kit.
NOTE: Airflow through the duct system is affected
by the duct length and number of bends. Keep
the length and bends to a minimum to maximize
performance.
MINIMUM FRAMING
CLEARANCES
*
Wall studs must be 407mm on center for mount-
ing fan housing.
* Fan Housing: Maintain a 6mm clearance from
fan housing to combustible material.
* Wall Registers must be 102mm above floor and
/ or 102mm below ceiling.
1. Determine the location of the air register/fan
housing assembly. Cut a 121mm x 406mm hole
between framing members (wall studs or floor
joists). Maintain a 6mm clearance from fan
housing to combustible material. See Framing
Clearances section.
MINIMUM FAN DUCT
CLEARANCES
The fan ducting requires a minimum of
25mm clearance to combustibles.
Minimum 102 mm
1
GF1500
Maximum Duct Run: 9.0m
Kit Contains 4.5m
Wall
Wall
Register
Register
Minimum 102 mm
from ceiling
from floor
07 february 22