4 Parts Replacement
4.3.2
Replacing Maintenance Cover Sensor
(1) Replacing Maintenance Cover Sensor R
1. Remove the maintenance cover U.
"4.2.3 Removing Maintenance Cover U" p.4-10
2. Detach the connector for the maintenance cover sensor assembly.
3. Remove the screws (2 pieces) that retain the maintenance cover sensor assembly.
No.
1
2
3
4. Remove the maintenance cover sensor assembly.
5. Replace the maintenance cover sensor assembly.
6. To reassemble the unit, reverse the removal procedure.
The maintenance cover sensor looks like the following.
Rev.-05
2
1
Maintenance cover sensor assembly
Screws that retain the maintenance cover sensor assembly
(pan-head screw with spring washer and flat washer M2
6)
Connector for the maintenance cover sensor assembly
Opened
Part name
4-32
VJ-1604 Maintenance Manual
3
×
Closed