Panasonic KX-TD500CE Programming Manual page 27

Digital super hybrid system
Hide thumbs Also See for KX-TD500CE:
Table of Contents

Advertisement

Parameter
Default
Value Range
Description/Function
Reference
Parameter
Default
Value Range
Description/Function
Reference
Parameter
Default
Value Range
Description/Function
Reference
Configuration
DN
Blank
3-4 digits consisting of 0-9 or X
Specifies the DN (Directory Number) for the BRI port.
(Assignable only when "EXT" is specified in "Type" assignment.)
Note
• "X" can be used as a wild card character which substitutes any
digit in its position. The last one or two digits of DN may be
"X."
• 2.3 Numbering Plan (P/G)
Group No.
1
1-48 or 1-128
Type: CO
Specifies the Trunk Group (1-48) to which the BRI port is assigned.
Type: EXT
Specifies the Extension Group (1-128) to which the BRI port is
assigned.
• 1.3 System Features (F/G)
– Extension Group
– Trunk Group
• 3.2 Trunk Group (P/G)
• 3.3 Extension Group (P/G)
Status
1.
INS
2.
OUS
3.
FAULT
Specifies the operating status of the BRI port.
1.
INS: The BRI port is In-Service.
2.
OUS: The BRI port is Out-of-Service.
3.
FAULT: The BRI port is defective (hardware).
In this case, the LED indicator on the BRI card will light.
None
1.8 BRI Port Assignment
27