3.3 Extension Group
Parameter
Default
Value Range
Description/Function
Reference
Parameter
Default
Value Range
Description/Function
Reference
118
FDN
Blank
3-4 digits consisting of 0-9
Specifies the FDN (Floating Directory Number) for the Extension
Group.
• 1.3 System Features (F/G)
– Floating Station
Group Type
Group No.126: VM, Group No.127: AA, Group No.128: Operator,
Others: None
1.
None
2.
Terminate
3.
Circular
4.
Ring
5.
Operator
6.
VM
7.
AA
8.
UCD
Specifies the Group Type for each Extension Group.
This determines how the Extension Group handles the incoming
calls directed to it.
1.
None:
No Group Type is specified.
2.
Terminate:
Functions as a Station Hunting Group (Terminate).
3.
Circular:
Functions as a Station Hunting Group (Circular).
4.
Ring:
Functions as a Ring Group.
5.
Operator:
Functions as an Operator Group.
6.
VM:
Functions as a VM (Voice Mail) Group.
7.
AA:
Functions as an AA (Automated Attendant) Group.
8.
UCD:
Functions as a UCD (Uniform Call Distribution) Group.
•1.3 System Features (F/G)
– Extension Group