Step 1
 Replace the UBA 3 by a UBA 3 provided with the most recent software possible.
Step 2
Has the fault been remedied?
Step 3
Diagnosis: The KIM is too new for the UBA 3. Measure: Contact the manufacturer. See the back of this
document.
section 63
e
[9/l/\|
[2/3/4|
Step 1
 Check the plug-and-socket connection of the gas valve, see section 109.
Step 2
Is the plug-and-socket connection okay?
Step 3
Diagnosis: The plug-and-socket connection has come loose.
Action: Replace the plug-and-socket connection, see section 109.
Step 4
 Check the electrical resistance of the power supply cord of the gas valve as indicated in section 111.
Step 5
Is the wire okay?
Step 6
Diagnosis: The wire harness is defective. Action: Replace the wire harness or the affected part.
Step 7
 Check the electrical resistance of the gas valve coils as indicated in section 111.
Step 8
Is the resistance correct?
Step 9
Diagnosis: The gas valve is defective. Action: Replace the gas valve, see section 113.
section 64
[a/0/1|
e
[8/1/0|
Step 1
 Check that no hot-water tap is dripping and that there is no leakage in the hot-water pipe.
This can be checked by feeling whether the hot-water pipe is hot at half a metre below the boiler.
Step 2
Is a hot-water tap dripping or is there a leakage in the hot-water pipe?
Step 3
Diagnosis: The hot-water tap is dripping or the hot-water pipe is leaking.
Action: Fix the dripping hot-water tap or the leakage in the hot-water pipe.
Step 4
 Check the electrical resistance of the DHW temperature sensor as indicated in section 93.
Step 5
Is the electrical resistance of the DHW temperature sensor okay?
Step 6
Diagnosis: The DHW temperature sensor is defective.
Action: Replace the DHW temperature sensor, see section 95.
Step 7
 Check the movement of the servomotor of the three-way valve.
Step 8
Does the servomotor of the three-way valve move?
Step 9
 Check that the three-way valve has been installed correctly.
Step 10
Has the three-way valve been installed correctly?
Logamax plus GB162-80 kW/100 kW - Subject to modifications resulting from technical improvements!
Locking fault code: The KIM is too new for the UBA 3 (section 1, [32]).
Locking fault code: The contacts of the gas valve (section 1, [21]) are open.
Blocking fault code: 4 hours of continuous DHW operation, while a heat demand also occurred
at the same time. The DHW operation has been switched off after this period of 4 hours, for as
long as the boiler is active for the heating operation.
Diagnosis
6
Yes:
Section 67
No:
Step 3
Section 67
Yes:
Step 4
No:
Step 3
Section 67
Yes:
Step 7
No:
Step 6
Section 67
Yes:
Section 66
No:
Step 9
Section 67
Yes:
Step 3
No:
Step 4
Section 67
Yes:
Step 7
No:
Step 6
Yes:
Step 9
No:
Step 12
Yes:
Step 18
No:
Step 11