Nb-Designer Function List - Omron NB-series Operation Manual

Nb-series programmable terminals
Hide thumbs Also See for NB-series:
Table of Contents

Advertisement

Appendices
A-2

NB-Designer Function List

Parts
Bit Button
Bit Lamp
Bit Switch
Command Button
Word Lamp
Word Switch
XY Graph
Moving
Component
Animation
Number Input
Number Display
Text Input
Text Display
Level Meter
Analog Meter
Indirect Screen
Direct Screen
Alarm
Data Log
Recipe
Oscillograph
A-6
Items
Operations such as the touch input allow the specified bit address turned
ON/OFF.
Indicates the specified ON/OFF state of one bit address.
Operations such as touch input allow the specified bit address turned
ON/OFF. Specify the Read/Write addresses separately to operate them as
the lamp.
Function Component performs several processing such as transmission of
constant value.
Function Component switches the display status according to the change
with value of the communications address.
Function Component performs increase and decrease of the value or
transmission of the value selected from the list.
Describing a continuum from the value of the communications addresses as
each point of coordinates in the component area. The shape can be modified
dynamically.
Describing the vector graphics or the bit map from the value of the
communications addresses as point of coordinates. The shape can be
modified dynamically.
Draw the component with the specified track in the PT, and this position is
determined by the value of the preset path and the communication
addresses.
Display the specified value of the communication address. Also Entering
number by pop-up keyboard and pressing [ENTER] allow the communication
address modified.
Display the value of the specified communication address.
Set the value of the specified communication address to text string data. The
input data is saved to a consecutive memory with the "Read Address" as the
first address.
Display the value of the specified communication address as text string.
Display the value of the specified communications address in a bar chart
percentage style according to the set maximum and minimum values.
Display the value of the specified communication address by means of a
Analog Meter diagram.
Display the screen of the specified screen No. in pop-up screen.
Display the specified screen in pop-up screen.
Display the occurred alarm information in the specified area. The content
displayed by the Alarm Display component is the same as that displayed by
the Alarm component.
Obtain the values of periodically specified communications address and
display them in the graphic chart. The background communication still
continues to do when the current screen where the Data Log locates is
closed. Even after the switching the screen in which the Data Log component
located to another screen, if the screen in which Data Log component
located is refreshed, the sampling data which was obtained until switching
the screen can be displayed.
Used to transfer the data from the recipe memory of PT to PLC or PLC data
to the PT Recipe memory.
The Oscillograph functions similarly to the Data Log. But the data sampling
of the Oscillograph is valid only during the screen in which the Oscillograph is
located is displayed, which means that each time the screen is switched, the
sampling data will be deleted and a new sampling will be started.
NB-series Programmable Terminals NB-Designer Operation Manual(V106)
Descriptions of Function