3 Functions of NB-Designer
Channel
Sequence number
Ascending
Date/Time Display
Color Setting
Frame Setting
Border Setting
Data History Query
Indirect Reference
of Sampling Cycle
Note When the variable is specified in the sampling cycle, if the value cannot be obtained within the regulated
time, the value which was obtained previously will be used.
3-192
Descriptions of Display Properties
Refers to the channel number of the memory to be sampled, and the channel is up to 16.
Determines whether to display the No. of the sampling data information.
When this option is checked, the sampling data information will be displayed in the
ascending order, i.e. the latest sampling data will be displayed on the bottom.
Date
Checking in the checkbox allows the sampling date displayed in the
selected date format. The 3 formats are available, and YY, MM and
DD refer to the year, month and date respectively.
Date Separator
Selects the data separator with 3 formats available. For example:
11/06/24.
Time
Checking it means the sampling time will be displayed and the time
format can be selected. There are 3 formats available, and HH, MM,
SS and MS refer to the hour, minute, second and millisecond
respectively.
Sets the Background Color and Title Bar Color for the table respectively.
Sets the Frame Color and Width for the table.
Set the color, types, and width of Border, row spacing, and column spacing with the unit
of "pixel point". Checking in "Horizontal Line" check box means the border will be
displayed horizontally, and checking "Vertical Line" means the border will be displayed
vertically.
The historical sampled data stored in the external memory can be searched by address
of the word memory specified in "Data History Query" setting. The Word Length of the
specified memory address is 2 by default.
Query by File
With the "Query by File Name" being checked, it means to call out the
Name
data history sampled today or in the latest day when the value of
specified memory is 0, while the data history sampled in the last time
when the value of specified memory is 1, and so on.
Query by Date
When "Query by Date" is checked, the date will be input into the
specified memory and the data history corresponding to the date will
be called out. The date format is yyyymmdd, where yyyy, mm and dd
refer to year, month and date respectively.
When Indirect Reference is used, the sampling time will be read from the specified
memory.