3 Functions of NB-Designer
DrawType: Includes Standard, Track and Trend. The sampling methods vary with the types.
Draw Type
Standard
Track
Trend
Sampling Points: Refers to the number of the sampling point displayed in the screen.
PageNum: When [Multiple pages] is selected in [Type], this option is valid. And it ranges from 1
Channel: Refers to the number of track line to be displayed, and it corresponds to the word
Pause-Clear: Set the bit address to control the pause of creating a line graph or the clear of
Scroll: The address specified by this bit is used in combination with the scroll components, i.e.
Time: When "Save Time" is checked, the below "Time" option can be selected. This option
includes 12 words, and it is used to save the time for the latest sampling point currently.
"Second, minute, hour, day, month, year" for the starting point and "Second, minute,
hour, day, month, year" for the end point of the current page are stored in these 12 words
respectively, and each word represent a point in time.
3
Switch to the [Channel] tab and set the parameters related to each track line.
3-100
Multiple points are sampled each time, and X and Y components are included.
Number of the occupied memory depends on the number of channel and sampling
points. For example, if there are m channels and n sampling points, number of the
occupied memory is "m×n×2".
One point is sampled each time, and X and Y components are included. Number of
the occupied memory depends on the number of channel. For example, if there are
m channels and n sampling points, the number of occupied memory is "m×2".
Multiple points are sample each time, and only Y component instead of X
component is included. Number of the occupied memory depends on the number of
channel and sampling points. For example, if there are m channels and n sampling
points, number of the occupied memory is "m×n".
to 32767.
length of read address to be set. And 2 word addresses correspond to one track line.
The channel ranges from 1 to 16.
creating a graph. [Clear] bit address = [Pause] bit address + 1. When [Clear] bit
is ON, the sampling data will be cleared and when the bit turns OFF again, the
sampling will continue and the changes in XY Graph will be displayed
dynamically.
the XY Graph can be viewed by directly moving the scroll bar. The scroll address
should be set in consistent with the address used by the related scroll bar component.
For details, refer to [3-6-22 Scroll Bar].