2
Creating new Recipe file and Saving the file
When new Recipe file is created, the data type is needed to be specified. When the existing
Recipe file is read, the file's specification should be corresponded to the data type specified to
the file. If the file is specified the different data type, the contents of the file cannot be read
correctly.
The available file format to be edited by Recipe file are .rcp, .frp and .csv.
When RecipeEditor is opened for the first time, clicking
clicking
after the previous created file is saved. When opening the Recipe file, if [File] - [Open] is
selected in the state of the file is already opened, [Save as] dialog box will be opened and
[Open file] dialog box will be displayed. For the already saved files, the complete file path will
appear in the title bar.
3
Data type and changing data
For example, double-click the mouse at the red box during the edition to make the Record Edit
Dialog pop up, and then change Storage Format from "16 bit signed number" as the lower left
graphics shown to "16 bit Hexadecimal" as the lower right graphics shown.
NB-series Programmable Terminals NB-Designer Operation Manual(V106)
displayed in the title bar; while Save As dialog box will pop up if
(New) icon after the creation of recipe file. Therefore, create another recipe file only
3 Functions of NB-Designer