Removing The Convection Thermoactuator And The Wide Interface Board - KitchenAid KEMS378S Technical Education

27" & 30" electric built-in microwave/oven combination
Hide thumbs Also See for KEMS378S:
Table of Contents

Advertisement

REMOVING THE CONVECTION THERMOACTUATOR
AND THE WIDE INTERFACE BOARD
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug oven or disconnect power.
2.
Open the microwave oven door, remove
the two flat-head screws from the bottom
of the control panel frame, and remove the
frame.
Control Panel Frame Screws
3.
Remove the four screws from the front
subpanel and remove the subpanel as-
sembly.
Front Subpanel Screws
4.
Disconnect the P1 and P2 connectors from
the microwave and lower oven control board
connectors and set the panel assembly
aside.
Lower Oven Board
P2 P1
MW Oven Board
P2 P1
Convection Thermoactuator
WIDE Interface Board
5.
To remove the convection thermoactuator:
a) Disconnect the two wire connectors
from the terminals.
b) Remove the two screws and remove
the thermoactuator.
Wire Connectors
Thermoactuator Screws
6.
To remove the WIDE interface board:
a) Disconnect the two wire connectors at
P1 and U3.
b) Push and unlock the tab and remove the
WIDE interface board from its bracket.
4-5
P1
WIDE Interface Board
U3
Tab