Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
GRILL ELEMENT
Refer to page 4-16 for the procedure for ac-
cessing the grill element.
1.
Unplug oven or disconnect power.
2.
Disconnect one of the wires from the grill
element terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the grill
element terminals. The meter should indi-
cate approximately 9 Ω.
Electrical Shock Hazard
Grill Element
WARNING
LOWER OVEN LIGHT
TRANSFORMER
LOAD (Secondary)
Terminals
Refer to page 4-20 for the procedure for ac-
cessing the lower oven light transformer.
1.
Unplug oven or disconnect power.
2.
Disconnect one of the wires from the LINE
(primary) and one from the LOAD (second-
ary) terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the LINE
terminals. The meter should indicate ap-
proximately 40 to 45 Ω.
5.
Touch the ohmmeter test leads to the LOAD
terminals. The meter should indicate less
than 1 Ω.
5-7
LINE (Primary)
Terminals