Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
BROIL ELEMENT
Refer to page 4-30 for the procedure for ac-
cessing the broil element.
NOTE: The broil element will be tested at the
appliance manager board (see page 4-18).
1.
Unplug oven or disconnect power.
2.
Set the ohmmeter to the R x 1 scale.
3.
Touch the ohmmeter test leads to the wire
connectors. The meter should indicate as
shown below:
Inner Element: T3-4 (OR) and T1-1 (RD).
The meter should indicate between 31 and
36 Ω.
Outer Element: T3-1 (BU) and T2-2 (R/W).
The meter should indicate between 53 and
59 Ω.
T1
T3
1 2 3 4 5
Lower Oven
Appliance Manager
WARNING
Electrical Shock Hazard
OVEN TEMPERATURE SENSOR
Refer to page 4-30 for the procedure for ac-
cessing the oven temperature sensor.
NOTE: The oven temperature sensor will be
tested at the appliance manager board (see
page 4-18).
1.
Unplug oven or disconnect power.
2.
Set the ohmmeter to the R x 1K scale.
3.
Touch the ohmmeter test leads to P2-1 (V)
and P2-2 (V). The meter should indicate
approximately 1091 Ω @ 75°F (23.9°C).
Lower Oven
Appliance Manager
5-11
P2