REMOVING THE MAGNETRON FAN MOTOR & THE INVERTER
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug oven or disconnect power.
2.
Remove the oven from its mounting location
(see "Installation Information" in Section 2)
and pull it forward so that you can access
the top cover.
3.
Remove the four screws from the top cover
and remove the cover.
Screws (2 of 4)
4.
Remove the eight screws from the inner
cover and remove the cover.
Inner Cover Screws (3 of 8)
MW Appliance Manager Bracket
Magnetron Fan Motor
Top Cover
Inverter
5.
Remove the ten screws from the upper rear
cover of the oven and remove the cover.
Upper Rear Cover
6.
To remove the magnetron fan motor:
a) Remove the left screw from the appli-
ance manager board bracket.
App. Man. Board
Left Bracket Screw
b) Remove the magnetron fan motor
housing screw from the rear of the
chassis.
Continued on the next page.
4-13
(10 Screws)
Mag. Fan Motor
Housing Screw