Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
BLOWER SPEED RESISTOR
Refer to page 4-36 for the procedure for ac-
cessing the blower speed resistor.
NOTE: The blower speed resistor will be tested
at the appliance manager board (see page
4-18).
1.
Unplug oven or disconnect power.
2.
Set the ohmmeter to the R x 1 scale.
3.
Touch the ohmmeter test leads to wire con-
nectors P9-2 (GY) and P8-4 (GY). The meter
should indicate approximately 170 Ω.
Lower Oven
Appliance Manager
Electrical Shock Hazard
P9
P8
1 2 3 4 5
1 2 3 4 5 6
WARNING
OVEN SHUTDOWN THERMAL
CUTOFF (TCO)
Refer to page 4-36 for the procedure for ac-
cessing the oven shutdown thermal cutoff.
NOTE: The oven shutdown thermal cutoff will
be tested at the appliance manager board (see
page 4-18).
1.
Unplug oven or disconnect power.
2.
Set the ohmmeter to the R x 1 scale.
3.
Touch the ohmmeter test leads to wire con-
nectors T1-2 (R/W) and P7-3 (RD). The meter
should indicate a closed circuit (0 Ω).
Lower Oven
Appliance Manager
5-14
T1
P7