Removing The Monitor Fuse And The Microwave Appliance Manager - KitchenAid KEMS378S Technical Education

27" & 30" electric built-in microwave/oven combination
Hide thumbs Also See for KEMS378S:
Table of Contents

Advertisement

REMOVING THE MONITOR FUSE AND
THE MICROWAVE APPLIANCE MANAGER
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug oven or disconnect power.
2.
Open the microwave oven door, remove
the two flat-head screws from the bottom
of the control panel frame, and remove the
frame.
Control Panel Frame Screws
3.
Remove the four screws from the front
subpanel and remove the subpanel as-
sembly.
Front Subpanel Screws
4.
Disconnect the P1 and P2 connectors from
the microwave and lower oven control board
connectors and set the panel assembly
aside.
Lower Oven Board
P2 P1
MW Oven Board
P2 P1
Monitor Fuse
5.
To remove the monitor fuse holder:
a) Remove the fuse from the fuse holder.
b) Disconnect the two wire connectors
from the fuse holder terminals.
c) Remove the screw from the fuse holder
and remove the fuse holder.
BR
Fuse Holder Screw
6.
To remove the microwave appliance
manager:
a) Remove the two screws from the left
side of the board and remove the board
from its holder.
b) Disconnect the wire connectors from
the board (see below for the wiring).
Microwave Appliance Manager Screws
P3
RL1
RL2
BU-YL
BU
RD
WH
BK WH
(SM)
(LG)
P1=BU-BR
2 BK-2 BR & 4 BK
4-6
Microwave Appliance Manager
Monitor Fuse
RL3
P10
P8
BR
6-Pin
3-Pin
BR
HUM
3-Pin
P6
2-Pin

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kems308s

Table of Contents