6A1-12 ENGINE MECHANICAL (G13B, 1-CAM 16-VALVES ENGINE)
AIR CLEANER OUTLET HOSE
REMOVAL
1) Disconnect negative cable at battery.
2) Disconnect resonator after loosening its clamp.
3) Disconnect breather hose from air cleaner outlet hose.
4) Disconnect IAT sensor wire at coupler.
5) Remove bolt and then air cleaner outlet hose after loosening its
clamps.
INSTALLATION
Reverse removal procedure for installation, noting the following.
D Clamp each hose securely.