Data Field Descriptions - ADEMCO Lynx Installation Instructions Manual

Ademco lynx security system installation instructions
Hide thumbs Also See for Lynx:
Table of Contents

Advertisement

Defaults (where applicable) are Indicated in Text.
The following pages list all data fields in this Control (in numerical order). Use the blank programming form to
record the data for this installation. Note that both keypad LEDs flash while in Programming mode.
Installer code
* 20
Enter 4 digits, 0–9.
Quick arm enable
* 21
0 = do not allow quick arm
1 = allow quick arm
Keypad backlight timeout
* 22
0 = no timeout; always backlight keys
1 = turn backlighting off after inactivity
Forced bypass
* 23
0 = no forced bypass
1 = provide automatic bypass of all open
(faulted) zones
RF House ID Code
* 24
00 = disable all wireless keypad usage
01-31 = House ID
Powerline Carrier Device (x-10) house ID
* 25
0 = A, 1 = B, 2 =C, 3 = D, 4 = E, 5 = F, 6 = G, 7
= H, 8 = I, 9 = J, # + 10 = K, # + 11 = L, # + 12 =
M, # + 13 = N, # + 14 = O, # + 15 = P.
Chime by zone
* 26
0 = no (chimes on fault of any entry/exit or
perimeter zone when Chime mode activated)
1 = yes (chimes on fault of specific zones
programmed in Zone List 3 when Chime mode
activated)
Real time clock display
* 27
0 = do not display the time
1 = display the time
Daylight savings time start/end month
* 29
0, 0 = no daylight saving time used.
1-12 = start month and end month
Daylight savings time start/end weekend
* 30
0 = disable
1 = first weekend of month 5 = last weekend
2 = second weekend
3 = third weekend
Single alarm sounding per zone
* 31
(per armed period)
0 = no limit on alarm sounding per zone
1 = limit alarm sounding to once per arming
period for a given zone
Fire sounder timeout
* 32
0 = yes, fire sounder timeout after time
programmed in field *33
1 = no fire sounder timeout; continue sounding
until manually turned off
Alarm bell timeout
* 33
0 = No timeout
1 = 4 min
2 = 8 min
Exit delay
* 34
00-99 = exit delay time in seconds

Data Field Descriptions

The Installer Code is used to enter the 4-digit Master Security Code. See
"Master Code" in the System Operation section for procedure.
If enabled, security code is not required to arm the system. The user
simply presses and holds down the AWAY or STAY key to arm.
This option allows the choice of either always backlighting the keypad
or turning the backlighting off after 10 seconds of keypad inactivity.
All zones bypassed by this function will be displayed after the bypass is
initiated.
UL installations: must be 0 (no forced bypass)
The House ID identifies receivers and wireless keypads.
If a 5827 or 5827BD Wireless Keypad or 5804BD Transmitter is to be
used, a House ID Code MUST be entered, and the keypad should be set
to the same ID.
Powerline Carrier Devices require a House ID. This field identifies this
House ID to the Control.
Powerline Carrier Devices are programmed in field * 80.
This option allows the installer to define the specific zones intended to
chime when faulted while the system is in Chime mode. If enabled,
these zones are defined in zone list 3 (see *81 Zone List Programming
section).
Refer to the User's Manual for setting the clock time and date.
Enter # + 10 for 10, # + 11 for 11, and # + 12 for 12.
Enter the appropriate start and end weekend of the month.
4 = fourth weekend
6 = next to last
rd
7 = 3
from last
UL installations: must be 0 (no limit)
This field applies only to burglary zones (zone response types 1-5, 10).
This Control complies with NFPA requirements for temporal pulse
sounding of fire notification appliances.
Temporal pulse sounding for a fire alarm consists of the following:
3 pulses – pause – 3 pulses – pause – 3 pulses. . .
This field determines whether the external sounder will shut off after
time allotted, or continue until manually turned off.
3 = 12 min
UL installations: must be set for a minimum of 4 min (option 1)
4 = 16 min
The system will wait the time entered before sounding an alarm if the
exit door is left open after the system has been armed.
–15–