Mechanics of Programming

General Programming Information
Programming options are stored in nonremovable, electrically erasable, nonvolatile EEROM memory.
You can program the system at any time, even at the installer's premises prior to the actual installation. Simply apply
power temporarily to the Control and then program the unit as desired.
There are two programming modes:
• Data field programming (used for setting various system options)
• Interactive menu mode programming (used for programming zone information, programming Powerline Carrier
Devices, and for entering transmitter serial numbers)
You can also program this system remotely from the installer's office/home, using an IBM Personal Computer, a
modem, and V-LINK downloading software. See the Remote Programming/Control (Downloading) section.
Entering Program Mode
You may use one of the following methods:
a) Press both the [ ] and [#] keys at the same time within 50 seconds after power is applied to the Control, or
b) After power-up, enter the Installer Code (4 1 1 2) + 8 0 0.
This method is disabled if you exit the Program mode using *98 instead of *99.
If a different Installer Code is subsequently programmed, use it instead of 4112 to enter the Programming mode.
Following entry into Program mode, data field *20 will be displayed (this is the first data field in the system) and
both keypad LEDs will flash.
Programming a Data Field
1. Press [ ] + Field No. (for example, *21), then make the required entry.
2. When you have completely programmed a data field, the keypad will "beep" three times and then automatically
display the next data field in sequence. To go to a different field, press [ ] plus the desired field number.
3. If the number of digits that you need to enter in a data field is less than the maximum number of digits available
(eg. phone number field), enter the desired data, then press [ ] and the next data field number to be programmed.
4. If you enter a nonexistent field, the keypad will display "EE". Simply re-enter [ ] plus a valid field number.
To view a data field without making changes, press [#] + Field No. Data will be displayed for that field.
To delete an entry in a field, press [ ] + Field No. + [ ]. (Applies only to fields
Interactive Mode Programming (
Press [ ] + interactive mode No. (for example,
A detailed procedure (with displays of prompts) is provided in later sections of this manual.
Interactive Mode
56 Zone Programming
*
80 Device Programming
*
*
81 Zone List Programming
*
83 Sequential Mode
*84 Assign Zone Voice Descriptors
*85 Record Custom Voice Descriptors
Loading Factory Defaults
To load the factory defaults, enter the Programming mode, press
96 resets all the subscriber account numbers and CSID in preparation for an initial download.
*
Exiting the Programming Mode
*
99 allows re-entry into the Program mode using Installer Code + 8 0 0.
*
98 inhibits re-entry into the Programming mode using the Installer Code.
NOTE: To bypass the 1-minute reset delay, press [#] + [0].
Do not press
!
previously—data already programmed into the system will be changed!
56,
80,
81,
83, *84, *85)
*
*
*
*
56). The keypad will display the first of a series of prompts.
*
Used to Program
Zone characteristics, report codes, and serial numbers
Powerline Carrier Devices
Zone Lists for powerline carrier activation
5800 Series transmitter serial numbers
Voice descriptors for each zone
Up to 5 custom voice descriptors for zones
97 to load defaults if any programming has been done
*
–12–
*
40–
*
44 and
97, then select from tables 1-5 or select "0" to exit.
*
*
94).