ADEMCO Lynx Installation Instructions Manual page 14

Ademco lynx security system installation instructions
Hide thumbs Also See for Lynx:
Table of Contents

Advertisement

Type 08
24-hour
Auxiliary Alarm
Type 09
Supervised Fire
5806/5807/5808
Type 10
Interior w/Delay
Type 20
Arm–Stay
Type 21
Arm–Away
Type 22
Disarm
Type 23
No Alarm Response
Type 24
Silent Burglary
This zone type sends a report to the central station and provides an alarm sound at the
keypad. (No bell output is provided and there is no keypad timeout.) This zone type is
usually assigned to a zone containing a button for use in personal emergencies, or to a
zone containing monitoring devices such as water or temperature sensors, etc.
This zone type provides a fire alarm on short circuit and a trouble condition on open
circuit. The bell output will pulse when this zone type is alarmed. This zone type is always
active and cannot be bypassed. Any wireless zone can be used as a fire zone.
This zone type gives entry delay #1 (using the programmed entry time) if tripped when the
panel is armed in the AWAY mode. Entry delay begins whenever sensors in this zone are
violated, regardless of whether an entry/exit delay zone was tripped first. No entry delay is
provided if tripped when the panel is armed in the MAXIMUM mode. Exit delay is
present for any arming mode. This zone type is bypassed when the panel is armed in
the STAY or INSTANT mode.
This is a special-purpose zone type used with 5800 Series wireless pushbutton units which
will result in arming the system in the STAY mode when the zone is activated. Pushbutton
units send the zone number as a user number to the central station when arming or
disarming.
This is a special-purpose zone type used with 5800 Series wireless pushbutton units which
will result in arming the system in the AWAY mode when the zone is activated.
Pushbutton units send zone number as a user number to central station when arming or
disarming.
This is a special-purpose zone type used with 5800 series wireless pushbutton which will
result in disarming the system when the zone is activated.
This zone type can be used on a zone when a Powerline Carrier Device (e.g., X-10) action
is desired, but with no accompanying alarm (e.g., front door light).
This zone type provides an instant alarm, with NO audible indication at any keypad or
external sounder, if the zone is faulted when the system is armed in the AWAY, STAY,
INSTANT, or MAXIMUM modes. This zone type is usually assigned to all sensors or
contacts on exterior doors and windows where bells and/or sirens are NOT desired. A
report is sent to the central station. NOTE: When the system is disarmed and Chime mode
is on, the keypad will beep if the zone is faulted.