Wiring Connections
1. Phone Line Connections
Connect the incoming phone line to
either the RJ31X jack or terminals 2
(TIP) and 3 (RING).
Connect the handset phone lines to
either the RJ11 jack or terminals 4
(TIP) and 5 (RING).
2. Hardwired Zone Connections
Zone 1 is an EOLR supervised zone
that supports both open circuit and
closed circuit devices and has a
response time of 350msec.
Maximum zone resistance: 300
ohms, plus EOLR
a. Connect sensors/contacts to the
hardwired zone terminals 6 (+) and
7 (–). Refer to the Summary of
Connections diagram.
b. Connect closed circuit devices in
series in the high (+) side of the
loop. The EOL resistor must be
connected in series with the
devices, following the last device.
c. Connect open circuit devices in
parallel across the loop. The 2000
ohm EOLR must be connected
across the loop at the last device.
3. External Sounder Connections
The LYNX supports either a 6-
14VDC piezo sounder (30mA max.)
or 6-14VDC bell (120mA max.; e.g.
ADEMCO WAVE2EX).
Connect a piezo sounder to
terminals 10 (+) and 11 (–);
OR
Connect a bell to terminals 11 (–)
and 12 (+).
EARTH
GROUND
1
EARTH
GROUND
4. Powerline Carrier Device Connections
The LYNX supports up to 8 Powerline Carrier
Devices.
If using these devices, the LYNXrequires
connection of a PL513 Powerline Interface
Module, as shown in the SUMMARY OF
CONNECTIONS diagram.
Connect the com/data/sync/ lines from the
PL513 Powerline Interface Module to
terminals 9, 13, and 14.
Refer to the *80 Device Programming Menu
Mode section for details on programming
Powerline Carrier Devices.
HARDWIRED ZONE: If the EOLR is not at the end of the loop, the zone will not be
properly supervised, and the system may not respond to an open circuit on the
zone.
LOCAL SOUNDER DISABLE: The Master Keypad's built-in piezo sounder can be
disabled by cutting the white jumper on the terminal board.
If disabled, no sounding will occur upon AC loss, since the external sounder does
not operate when AC power is lost.
Wiring Connections
ZONE N/U
PHONE
2
3
4
5
6
7
8
9
TIP
RING
TIP
RING (+)
( )
(+)
( )
HARD
WIRED
ZONE
COM
FROM
PL513
INCOMING
HANDSET
PHONE
PHONE
LINE
LINE
30mA max.
2k OHMS
EOLR
LYNX Terminal Block
–7–
SOUNDERS PLCD
AC
10
11
12
14
15
13
16
(+)
( )
(+)
DATA
SYNC
OUT
IN
PLUG-IN
TRANSFORMER
(e.g., ADEMCO 1332)
9VAC
BELL
POWERLINE
PIEZO
15VA
CARRIER
DEVICES
NOTE: BACKUP BATTERY IS REQUIRED. USE
6-14VDC
6-14VDC
SINGLE 9V ALKALINE BATTERY (e.g., DURACELL
120mA max.
(e.g., WAVE2EX)
PC1604 PROCELL) OR SIX 1.5V ALKALINE "AA"
BATTERIES (e.g., DURACELL MN1500).
REPLACE BATTERY AT LEAST EVERY YEAR.