The following explains these prompts in detail. The left two columns identify the prompts and list the available
entries. The right-most column provides a further explanation of the entries.
NOTE: Entry of a number other than one specified will give unpredictable results.
Powerline Carrier Device programming
0 = exit mode
1 = enter mode
80
Device number
A 0I
01-08 = device number to be programmed
[*] = continue
00 = exit Device Programming mode
Device action
b
0 = No response
aa
1 = Close for 2 seconds
2 = Close and Stay Closed
3 = Continuous Pulse on & off (1 sec ON, 1
sec OFF)
[*] = continue
[#] = return to previous prompt
Start event type
C
et
0 = Not used
1 = Alarm
2 = Fault
3 = Trouble
[*] = continue
[#] = return to previous prompt
Start zone list
d
zl
1-3 = zone list number (to be programmed in
field *81)
0 = zone list not used for this device
[*] = continue
[#] = return to previous prompt
Start zone type
E
zt
01-58 = zone type to start this device action
00 = zone type not used for this device
[*] = continue
[#] = return to previous prompt
Stop zone list
F
zl
1-3 = zone list to stop this device action
0 = zone list not used
[*] = continue
[#] = return to previous prompt
Stop zone type
IA
zt
01-58 = zone type to start this device action
00 = zone type not used for this device
[*] = continue
[#] = return to previous prompt
Pressing 1 advances to the next prompt below.
Pressing 0 exits mode, upon which this prompt blinks, indicating the mode
is inactive. Press [*] + any field number to go to that field.
Enter device numbers as 2-digit entries.
Enter the 1-digit action (0-3) for the device being programmed (current
action is displayed).
Enter the 1-digit event type (0-3) to activate the device being programmed.
A zone list must be used in conjunction with an event. If a zone
type/system operation is to be used instead of an event, enter 0.
If a zone list will be used to start the device action, enter the zone list
number at this prompt.
If a zone type or system operation will be used to start the device action,
enter the appropriate 2-digit code for the device being programmed (see
table that follows).
Choices for zone types
00 = Not Used
04 = Interior Follower
01 = Entry/Exit #1
05 = Trouble Day/Alarm Night
02 = Entry/Exit #2
06 = 24 Hr Silent
03 = Perimeter
07 = 24 Hr Audible
Choices for system operation
20 = Arming–Stay
36 = At Bell Timeout** 42 = System Battery Low
21 = Arming–Away
38 = Chime
22 = Disarming (Code + OFF) 39 = Any Fire Alarm
31 = End of Exit Time
40 = Bypassing
32 = Start of Entry Time
33 = Any Burglary Alarm
** Or at Disarming, whichever occurs earlier
If a zone list will be used to STOP, or restore, the device action, enter the
zone list number 1, 2, or 3 (to be programmed in *81 mode). If not used,
enter 0.
If a zone type or system operation will be used to STOP the device action,
enter the appropriate 2-digit code (see the "ZT" choices listed above). If
not, enter 00.
The display then returns to the DEVICE NUMBER prompt (A) so that you
can enter the next device number to be programmed, or enter [0][0] to end
device programming.
–26–
08 = 24 Hr Aux
09 = Fire
10 = Interior w/Delay
24 = Silent Burglary
43 = Communication Failure
52 = Kissoff
58 = Duress