0 = must be zero
Number of reports in armed period
0 = reports limited to a total of 10
1 = unlimited number of reports
Flexible callback
0 = no flexible callback 2 = last 2 digits flexible
1 = last digit flexible
3 = last 3 digits flexible
Download call back phone number
Enter up to 20 digits as follows: 0–9, # +11 for
*
"
", # + 12 for "#", # + 13 for a pause.
Ring detection count for downloading
0-15 = number of rings before control picks up
phone line (15 = bypass answering machine)
ZONE PROGRAMMING MODE
Interactive menu mode used for programming zone attributes and report codes. Refer to the *56 Zone Programming
Mode section for procedure.
POWERLINE CARRIER DEVICE PROGRAMMING
Interactive menu mode for programming Powerline Carrier Devices. Refer to the *80 Device Programming Menu
Mode section for detailed procedure.
ZONE LISTS FOR OUTPUT DEVICES
Interactive menu mode for programming zone lists for Powerline Carrier Devices. Refer to the *81 Zone List Menu
Mode section for detailed procedure.
SEQUENTIAL MODE
Interactive menu mode used to enter RF transmitter serial numbers. Refer to the *83 Sequential Mode section for
detailed procedure.
ASSIGN ZONE VOICE DESCRIPTORS
Interactive menu mode used to assign descriptors to each zone. These descriptors will be announced whenever the
sytem announces an event involving a zone.
RECORD CUSTOM VOICE DESCRIPTORS
Interactive menu mode used to record custom descriptors for use with each zone.
INITIALIZE DOWNLOAD ID AND SUBSCRIBER ACCT. NO. FOR DOWNLOADING
Pressing *96 initializes the system for downloading.
SET ALL PROGRAM FIELDS TO 1 OF 5 SETS OF DEFAULT VALUES
See Default Tables at the end of this manual.
EXITS PROGRAMMING MODE
Prevents re-entry by : Installer Code + 8 + 0 + 0; allows re-entry only by Power-up, then [ * ] and [#].
EXITS PROGRAMMING MODE
Allows re-entry to program mode by: Installer Code + 8 + 0 + 0; or by Power-up, then [ * ] and [#].
This is a future option and must be set to 0. If this option is
inadvertently enabled, the Contact ID event code 606 may be sent to the
central station after an alarm report.
This option can be used to limit the number of messages (alarm & alarm
restore reports) sent to the central station in an armed period.
UL installations: must be 1 (unlimited reports)
If enabled, the control will ignore the last 1, 2, or 3 digits of the
programmed callback number (field *94) during a single download
session. This allows the download operator to temporarily change the
callback phone number by the number of digits selected, which allows
the control to call back similar, but different numbers during a single
session.
*
94,
*
95)
This is the phone number the control will use to call back the
downloading computer.
Do not fill unused spaces. End field by entering *. To clear entries from
field, press *94*.