Placing the HP NetServer in the Rack

Use this topic to place the HP NetServer safely in the rack. The following topics
provide instruction for installing the Cable Management Arm and Bezel.
WARNING
To prevent rack instability while mounting the HP NetServer
pull the rack's anti-tip foot forward out of the bottom. Failure
to do so could result in injury and equipment damage.
To prevent the rack from rolling while you mount the HP
NetServer, ensure the leveler screws on the rack's lower four
corners are in firm contact with the floor. See Figure 13-6.
1. Lower the leveler screws on the rack's lower four corners to make firm
contact with the floor. See Figure 13-6.
2. Ensure you have extended the anti-tip foot from the rack, before continuing
this procedure. See Figure 13-6.
Leveler
Screws (4)
3. Pull out both slides until the slide members are fully extended.
See Figure 13-6.
Figure 13-6. Pulling Out the Slides
Alternative Rack Mounting
Mounting
Tabs
Slide Members
153