HP NetServer LC 2000r Installation Manual page 57

Hp server user manual
Hide thumbs Also See for NetServer LC 2000r:
Table of Contents

Advertisement

Chapter 4
CAUTION
Use caution when handling the drive to prevent damage to the
fragile light pipes as you insert the drive.
5. Gently slide the drive module into the cage and stop when you feel
resistance. See Figure 4-11.
6. Verify the pin behind the pivot end of the handle engages the hole in the
edge of the cage.
7. Press the ejector handle in until you feel the latch click into place.
Closing the ejector handle engages the drive with the electrical connector
in the Hot Swap drive cage and seats the drive.
8. If the drive is unseated in the cage after closing the ejector handle, repeat
this procedure from Steps 4 to 7.
The handle was probably not pulled out far enough, and the locking latch
failed to engage the Hot Swap mass storage cage.
NOTE
Closing the ejector handle engages the drive with the electrical
connector in the Hot Swap mass storage cage and seats the
drive.
Figure 4-11. Inserting the Drive
Installing Mass Storage Devices
49

Advertisement

Table of Contents
loading

Table of Contents