Attaching The Mounting Handles; Placing The Hp Netserver In The Rack - HP D7171A - NetServer - LPr Installation Manual

Compaq 4000/ 7000 series racks installation guide
Hide thumbs Also See for D7171A - NetServer - LPr:
Table of Contents

Advertisement

Chapter 3

Attaching the Mounting Handles

Attach the four sheet metal mounting handles to the sides of the server. Each
handle requires two Phillips head screws. See Figure 3-10.
Figure 3-10. Attaching the Mounting Handles

Placing the HP NetServer in the Rack

Use this procedure to position the HP NetServer into the extended slides and
secure the chassis to the slides. Once the NetServer is in the rack, then you
connect the Cable Management Arm to the rear of the NetServer.
WARNING
To prevent rack instability while mounting the HP NetServer
pull the rack's anti-tip foot forward out of the bottom. Failure
to do so could result in injury and equipment damage.
To prevent the rack from rolling while you mount the HP
NetServer, ensure the leveler screws on the rack's lower four
corners are in firm contact with the floor. See Figure 3-9.
1. Lower the leveler screws on the rack's lower four corners to make firm
contact with the floor. See Figure 3-11.
2. Ensure you have extended the anti-tip foot from the rack, before
continuing this procedure. See Figure 3-11.
Rack-Mounting the HP NetServer
21