Access > User Properties >

User Name

This menu allows the master user to program the user's
name. A maximum of 16 characters can be entered in this
field. Use the [←] and [→] keys to scroll the cursor left and
right to view the entire user name.
The text programming procedure is very similar to that of
most mobile phones. Refer the Programming Text section
on page 10 for more details.
User names are stored with associated events in the
system's history log. This enables accurate auditing of user
movements at a later time if required. Names are also used
when reporting alarms and arm /disarm events in SMS and
other text based reporting formats.
Each user has a default name which can be changed if
desired. The default names are as follows.
DE FAU LT USER NA MES
User Number
1
2
48
Table 8: Default User Names
To change a user name,
1.
Enter [Master PIN] + [MENU]
2.
Enter [1] + [4] + [0] + [OK].
The keypad will display the Ur = prompt.
Enter the user number who's name you want to
change, then press [OK].
3.
The keypad will display the current User Name.
Use the [←] and [→] keys to view the existing
user name. The cursor position is indicated by the
flashing character in the name. It is possible to edit
a single character in the name without re-enetering
the entire name.
4.
Use the 0 to 9, [←] and [→] keys to change the user
name text as required. At any time you can use the
[↑] and [↓] keys to scroll through the complete list of
available characters.
5.
To clear all text from the cursor position to the right,
press the [OFF] key.
6.
When the user name is complete, press [OK] to save
and exit, or press [MENU] to exit without saving.
14
Ur AME
MENU 1-4-0
Default Name
USEr 1
AmE
USEr 2
AmE
USEr 48
AmE
Ur=
USEr 5
Access > User Properties >

Area Assignment

This menu allows the master user to program which areas
(1 to 4) a user can control. Each user can be assigned to one
or multiple areas. The master user can only assign another
user to any one or multiple areas that the master user has
been assigned to. At factory default, each user is assigned
to operate Area 1.
1. Enter [Master PIN] + [MENU]
2.
Enter [1] + [4] + [1] + [OK].
The keypad will display the Ur = prompt.
Enter the user number who's area assignment you
want to change, then press [OK].
2. The keypad will display the current area assignment
for the selected user. The numbers 1 to 4 on the
display correspond to areas 1 to 4.
1 2
3. Pressing buttons 1 to 4 will toggle the area
assignment on and off. When the number is
displayed, the user will have access to the area,
when the number is off the user will not have access
to the area.
4. Repeat Step 3 until you have assigned the user to all
required areas.
5. Press [OK] to save and exit, or press [MENU] to exit
without saving.

Timer Groups

Timer Groups can be used to prevent selected users from
operating the system outside given times of the day, days
of the week or even holiday periods.
This functionality needs to be configured on your system by
the installer, however master users can assign other users
to a specific timer group as well as adjust the schedule
times and days in which users in the group can operate the
system.
Multiple schedules can be associated to a timer group,
however users can only belong to one timer group. For
example, to allow a group of users to operate the system
between 8am and 5pm on Mon, Tue, Wed and Fri, 1 schedule
(Sh1) is required. To allow operation between 8am and
9.30pm on Thu, a second schedule (Sh2) is required.
Once the schedule(s) have been created, your installer will
link them to a timer group, and advise you which timer
group number has been used.
Master users can now restrict the user(s), by linking them
to the appropriate timer group.
UrArEA
MENU 1-4-1
Ur=
-Bit-
4
Bosch Security Systems 10/07 BLCC500U FTR1.01