Schedules

Schedules can be used to automatically operate outputs
or arm and disarm different areas at different times. When
linked to Timer Groups they can be used to control a users
access to the system. For example you may like to restict
staff from accessing the building on Sundays.
The control panel has up to 8 schedules available. Each
schedule includes a start and stop time, a day of the week
and holiday option which are used to set which days they
will operate.
Your installer will configure the schedules and other
parameters during installation, however master code users
are able to make adjustments to the schedules if required.
The following menus will show how to make adjustments
to the schedule name, the start and stop time, the days
of the week the schedule will operate, Holiday names and
holiday dates.
Your installer will advise you if your system has been
configured to use schedules.
System > Schedules >

Name

This menu allows the master user to program the schedule's
name. A maximum of 16 characters can be entered in this
field. Use the [←] and [→] keys to scroll the cursor left and
right to view the entire name.
The text programming procedure is very similar to that of
most mobile phones. Refer the Programming Text section
on page 10 for more details.
Schedule names are stored with associated events in the
system's history log. This enables accurate auditing of
events at a later time if required. Names are also used when
reporting alarms and arm /disarm events in SMS and other
text based reporting formats.
Each schedule has a default name which can be changed if
desired. The default names are as follows.
DE FAULT SCHEDUL E NA MES
Schedule Number
1
2
8
Table 12: Default Schedule Names
1.
Enter [Master PIN] + [MENU]
2.
Enter [7] + [5] + [0] + [OK]. The keypad will display
the sh = prompt. Enter the Schedule number you
want to program, then press [OK].
28
ShNAme
MENU 7-5-0
Default Name
Schedule 1 NAme
Schedule 2 NAme
Schedule 8 NAme
Sh=
3.
The keypad will display the current Schedule Name.
Use the [←] and [→] keys to view the existing name.
The cursor position is indicated by the flashing
character in the name. It is possible to edit a single
character in the name without re-enetering the
entire name.
4.
Use the 0 to 9, [←] and [→] keys to change the
Schedule Name text as required. At any time you
can use the [↑] and [↓] keys to scroll through the
complete list of available characters.
5.
To clear all text from the cursor position to the right,
press the [OFF] key.
6.
When the Name is complete, press [OK] to save and
exit, or press [MENU] to exit without saving.
System > Schedules >

Time

This menu allows you to program the start time and stop
time for of each schedule. Some schedules like those used
to automatically arm the system, will only have a start
time.
You should discuss the configuration of any schedules on
your system with your installer.
The following prompts will be shown when entering the
schedule time parameters.
Shh = Start Time Hours
Smm = Start Time Minutes
Ehh = End Time Hours
Emm = End Time Minutes
1.
Enter [Master PIN] + [MENU]
2.
Enter [7] + [5] + [1] + [OK]. The keypad will display
the sh = prompt. Enter the Schedule number you
want to program, then press [OK].
3.
Enter the schedule start time hours in 24hr format.
Allowable values are 01 to 23.
4.
Enter the schedule start time minutes.
Allowable values are 01 to 59.
SchedV
Shtime
MENU 7-5-1
Sh=
Shh=00
SMM=00