Selector
No.
1
Not used.
2
Detection enabled time for CNG
and no tone
3
4
Not used.
5
6
Registration of station ID
7
Tone sound monitoring
8
- Selectors 2 and 3: Detection enabled time for CNG and no tone
After the line is connected via the external telephone or by picking up the handset of the machine,
the machine can detect a CNG signal or no tone for the time length specified by these selectors.
The setting specified by these selectors becomes effective only when selector 8 on WSW20 is set
to "1."
- Selector 6: Registration of station ID
Setting this selector to "0" permits the registration of station ID for Austrian and Czech models.
- Selectors 7 and 8: Tone sound monitoring
These selectors set monitoring specifications of the tone sound inputted from the line.
WSW18
(Function setting 3)
Function
App. 4-22
Setting and Specifications
No. 2
3
0
0
:
40 sec.
0
1
:
0 sec. (No detection)
1
0
:
5 sec.
1
1
:
80 sec.
0:
Permitted
No. 7
8
0
X :
No monitoring
1
0
:
Up to phase B at the
calling station only
1
1
:
All transmission phases
both at the calling and
called stations
1:
Prohibited
Confidential