Brother DPC-8060 Service Manual page 413

Table of Contents

Advertisement

Selector
No.
1
Min. detection period required
for interpreting incoming
calling signal (CI) as OFF
2
3
Max. detection period for
incoming calling signal (CI)
being OFF
4
5
Min. detection period required
for acknowledging incoming
calling signal (CI) as ON
6
Line connection timing
7
(Not used.)
8
Not used.
- Selectors 1 through 4: Min. detection period required for interpreting incoming calling signal (CI) as
If the machine detects the OFF state of a CI signal for the period greater than the value set by
selectors 1 and 2 and less than the value set by selectors 3 and 4, it interprets the CI signal as OFF.
- Selectors 5 and 6: Min. detection period required for acknowledging incoming calling signal (CI) as ON
These selectors set the period required to make the machine acknowledge itself to be called. That
is, if the machine continuously detects a CI signal with the frequency set by selectors 1 through 4
on WSW14 during the period set by these selectors 5 and 6, then it acknowledges the call.
WSW12
(Signal detection condition setting)
Function
OFF
Max. detection period for incoming calling signal (CI) being OFF
App. 4-16
Setting and Specifications
No. 1
2
0
0
:
1500 ms
0
1
:
500 ms
1
0
:
700 ms
1
1
:
900 ms
No. 3
4
0
0
:
6 sec.
0
1
:
7 sec.
1
0
:
9 sec.
1
1
:
11 sec.
No. 5
6
0
0
:
800 ms (1000 ms*)
0
1
:
200 ms
1
0
:
250 ms
1
1
:
150 ms
0: Ringer-OFF
period (default)
1: Ringer-ON
period
*1000 ms in Chinese models.
Confidential

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfc-8460nMfc-8860dnMfc-8870dwDcp-8060Dcp-8065dn

Table of Contents