Brother DPC-8060 Service Manual page 402

Table of Contents

Advertisement

Selector
No.
CNG detection when sharing a
1
modular wall socket with a
telephone
2
Detection time length of
PABX* dial tone, required
|
for starting dialing
(Not used.)
4
CNG detection when sharing
5
a modular wall socket with a
telephone
6
Dial tone detection in
PABX* (Not used.)
7
8
Not used.
NOTE: Selectors 2 through 4, 6 and 7 are not applicable where no PABX is installed.
- Selectors 1 and 5: CNG detection when sharing a modular wall socket with a telephone
These selectors determine whether or not the machine detects a CNG signal when a line is
connected to a telephone sharing a modular wall socket with the machine. Upon detection of CNG
signals by the number of cycles specified by these selectors, the machine interprets CNG as an
effective signal and then starts FAX reception.
Selector
No. 1 No. 5
0 (A) 0 (A)
0 (A) 1 (B)
1 (B) 0 (A)
1 (B) 1 (B)
- Selectors 2 through 4: Detection time length of PABX dial tone, required for starting dialing
Upon detection of the PABX dial tone for the time length set by these selectors, the machine starts
dialing.
These selectors are effective only when both selectors 6 and 7 are set to "1" (Detection).
WSW03
(PABX* mode setting)
Function
(Not used.)
App. 4-5
Setting and Specifications
0: A
No. 2 3 4
0 0 0 :
0 0 1 :
0 1 0 :
0 1 1 :
1 0 0 :
1 0 1 :
1 1 0 :
1 1 1 :
0: A
No. 6 7
0 0
: No detection (3.5 sec. WAIT)
0 1
: No detection (5 sec. WAIT)
1 0
: No detection (7 sec. WAIT)
1 1
: Detection (Frequency only)
* PABX: Private automatic branch exchange
Cycle
0.5 cycle
1.0 cycle
1.5 cycles
2.0 cycles
1: B
50 ms
210 ms
500 ms
800 ms
900 ms
1.5 sec.
2.0 sec.
2.5 sec.
1: B