5.7.4 ADF OUTPUT CHECK: SP6008

1. Open SP mode SP6008.
2. Select the SP number that corresponds to the component you wish to check.
(Refer to the table below.)
3. Press On then press Off to test the selected item. You cannot exit and close
this display until you click Off to switch off the output check currently executing.
Bit
7 6 5 4 3 2 1 0
Data
1 1 0 0 1 0 1 0
No.
Description
1
Feed Motor: Forward
2
Feed Motor: Reverse
3
Transport Motor: Forward
4
Exit Motor: Forward
5
Pick-up Motor: Reverse
6
Bottom Plate Motor: Forward
7
Bottom Plate Motor: Reverse
SM
0
OFF
OFF
OFF
OFF
OFF
OFF
OFF
5-171
B064 Series/B140 Series/G126
INPUT/OUTPUT CHECK
1
ON
ON
ON
ON
ON
ON
ON