Sc600: Data Communication - Ricoh B064 Service Manual

Ricoh mfp service manual
Hide thumbs Also See for B064:
Table of Contents

Advertisement

SC600: Data Communication

SC No.
610
D
BICU
ADF communication/timeout abnormal
After 1 data frame is sent to the
ADF, an ACK signal is not received
within 100 ms, and is not received
after 3 retries.
611
D
BICU
ADF communication/break reception abnormal
During communication a break
(Low) signal was received from the
ADF.
612
D
BICU
ADF communication/command abnormal
A command that cannot be
executed was sent from the main
machine to the ADF.
620
D
BICU
ADF communication/timeout error
After 1 data frame is sent to the
finisher MBX, an ACK signal is not
received within 100 ms, and is not
received after 3 retries.
621
D
BICU
Finisher communication/break error
During communication with the
finisher MBX, the BICU received a
break (Low) signal from the finisher.
623
D
BICU
Tray 1~4 communication/timeout error
After 1 data frame is sent to the
trays, an ACK signal is not received
within 100 ms, and is not received
after 3 retries.
624
D
BICU
Tray 1~4 communication/break reception error
During communication with the
finisher trays, the BICU received a
break (Low) signal.
626
D
BICU
LCT communication/timeout error
After 1 data frame is sent to the
LCT, an ACK signal is not received
within 100 ms, and is not received
after 3 retries.
627
D
BICU
LCT communication/break reception error
During communication with the
LCT, the BICU received a break
(Low) signal.
630
C
RSS communication error
An error was detected in
communication via RSS between
the machine and the RSS center.
Error occurred on a public line at
the RSS terminal.
SM
B140 SERIES AND G126 SERVICE MODE
Symptom
4-51
Possible Cause
• Serial line connection unstable
• External noise on the line
• Serial line connection unstable
• Harness disconnected or defective
• A software error, result of an abnormal
procedure.
• Serial line connection unstable
• External noise on the line
• Serial line connection unstable
• External noise on the line
• Serial line connection unstable
• External noise on the line
• Serial line connection unstable
• External noise on the line
• Serial line connection unstable
• External noise on the line
• Serial line connection unstable
• External noise on the line
• No action required
B064 Series/B140 Series/G126

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents