Adf Input Check: Sp6007 - Ricoh B064 Service Manual

Ricoh mfp service manual
Hide thumbs Also See for B064:
Table of Contents

Advertisement

INPUT/OUTPUT CHECK

5.7.3 ADF INPUT CHECK: SP6007

1. Open SP mode SP6007.
2. Select the SP number that corresponds to the component you wish to check.
(Refer to the table below.)
3. Press On then press Off to test the selected item. You cannot exit and close
this display until you click Off to switch off the output check currently executing.
Bit
7 6 5 4 3 2 1 0
Data
1 1 0 0 1 0 1 0
Group 1
No.
0
Original Length Sensor 3 (LG)
1
Original Length Sensor 2 (A4)
2
Original Length Sensor 3 (B5)
3
Original Set Sensor
4
Original Width Sensor 1
5
Original Width Sensor 2
6
Original Width Sensor 3
7
Original Width Sensor 4
Group 2
No.
0
Skew Correction Sensor
1
Interval Sensor
2
Registration Sensor
3
Exit Sensor
4
DF Position Sensor
5
APS Start Sensor
6
Feed Cover Sensor
7
Pick-up Roller HP Sensor
Group 3
No.
0
Bottom Plate HP Sensor
1
Bottom Plate Position Sensor
2
Not Used
3
Not Used
4
Not Used
5
Not Used
6
Not Used
7
Not Used
B064 Series/B140 Series/G126
Description
Description
Description
5-170
SM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents