REPLACEMENT AND ADJUSTMENT

3.9 ANTI-STATIC BRUSH

[B]
[A]
[C]
[F]
[G]
[D]
[E]
B660R109.WMF
1. Pull out the Z-folding mechanism. (
3.2)
2. Open the left vertical transport cover [A].
3. Open the vertical transport assembly [B].
4. Remove the left link screw [C] of the vertical transport assembly.
5. Remove the right link screw [D] of the vertical transport assembly.
6. Remove the link screw [E] between the plates of the vertical transport assembly.
7. Remove the bracket [F].
8. Remove the anti-static brush [G].