Life Fitness 9100/9500HR Belt Drive Stairclimbers
DIAGNOSTIC MODE
ACCESS AND EXECUTION
Machine Statistics
7. Pressing the '3' key during the 'walking LED' test will initiate the Machine statistics test.
a. The machine usage data (total floors climbed) and machine total accumulated time in hours will be displayed
in the two upper (FPMG & TIME) display windows. Usage data and time in the (1-9999) range will be
displayed I the upper right (TIME) display window. When the data exceeds 9999, the 10K range will be
displayed in the upper left (FPMG) display window.
b. When the oiler option is enabled, the total number of cycles will be displayed in the lower right (CALORIE)
display window.
c. If the units non-volatile memory chip has failed or missing, the values displayed (a. & b.) will reflect machine
usage since the last time the unit lost power and the VF message center will identify the EEROM failure.
d. Pressing the "ENTER' key will activate the oiler pump for the prescribed (96 sec.) period. During this time the
minutes and seconds lapsed in the manual oil cycle will be displayed in the 'TIME' window on the Console.
The 'CALORIE' window on the console will be updated to reflect the additional oiling cycle performed.
e. Pressing the '1' key will clear the machine usage data (total floors climbed) recorded in the non-volatile
memory.
f.
Pressing the '2' key will clear the number or oil cycles recorded in non-volatile memory.
Pressing the 'CLEAR' key will exit the Oiler Primer Test and return the unit to the 'walking LED' test.