Life Fitness 9100/9500HR Belt Drive Stairclimbers
TROUBLESHOOTING GUIDE
Symptom: ERRATIC OR NO TELEMETRY READING
Symptom
No chest strap detected
Erratic Heart Rate readings
(Cross Talk)
Probable Cause
Chest strap sensor not making
good contact with body of user.
Lose connection at receiver
User is out of monitoring range
Faulty receiver
Faulty chest strap
Bad connection between
receiver and display
Faulty display console
Stairclimbers are to close
Corrective Action
Adjust chest strap.
Moisten sensor to make better contact with
skin.
Check connection at receiver.
Move within three feet (1 meter) of receiver.
Replace receiver.
Replace chest strap.
Inspect HR cable. Check HR in diagnostics.
Switch display with another LS 9500HR that is
functioning properly.
Test with an pulse simulator.
Position Stairclimbers at recommended
distances.(See Operation Manual)
For Assistance Contact
Life Fitness Customer Support Services
Teleph.: 847.451.0036 or 800.351.3737
Telefacs.: 847.288.3702 or 800.216.8893