EPSON Stylus Pro 7500
ADJ CAP POSITION
Use this function to check the actual capping position and correct the capping position
parameter in the firmware if necessary.
n
When the cleaning operation positions do not match, this
adjustment becomes necessary.
n
When this adjustment is completed, the corrected value is
written automatically.
n
To confirm the cap position, after carrying out this adjustment,
turn the power on again, then when the carriage stops at the
home position, check if the CR is locking.
1.
Make sure "Adj Cap Position" appears on the LCD and press the Enter button.
2.
The printer begins the HP detection sequence and automatically detects the capping
position, adjusting the logical position if necessary.
3.
After the adjustment process is finished, the detected distance between the HP and the
capping position is displayed.
4.
Do one of the following:
> Press the Enter button to update the capping position parameter and proceed to the
next menu item, or
> Press the Pause button to avoid updating the capping position parameter and return to
the beginning; "Adj Cap Position" appears on the LCD
5.
Turn the power switch OFF.
Adjustment
Figure 5-14. Cap Position Check Operation
Adjustment Steps
Revision A
193