EPSON Stylus Pro 7500
5.2.6.2 PF Timing Belt Tension Adjustment
This adjustment is necessary for service operations that require you to remove/loosen the
PF Motor or PF Belt. When replacing or re-installing the PF Belt, you need to confirm the
tension of the PF Belt.
Standard:
2,200g ± 10%
(Tension in the PF motor mounting plate moving direction.)
Figure 5-45. PF Belt Tension
Adjustment
Loosen the srews (x4) fixed to the PF
moter mounting board and set the
tension gauge to the hole on the
board and pull to the movable
direction. 2.200g ±10%
Adjustment Steps
Revision A
221