Removing The P_Rear Sensor Assy; Removing The Front Cover Sensor Assy - Epson StylusPro 10000 Service Manual

Table of Contents

Advertisement

EPSON Stylus Pro 10000/10000CF

4.2.3.23 Removing the P_REAR Sensor ASSY

1.
Remove the R Side Cover as described in "R Side Cover Removal 124.
2.
Remove the L Side Cover as described in "L Side Cover Removal 124.
3.
Remove the H Top cover as described in "H Top Cover Removal 123.
4.
Remove the Rear Cover as described in"Rear Cover Removal 126.
5.
Remove the Paper Guide U as described in "Removing Paper Guide U 131.
6.
Disconnect the cable for the P_REAR Sensor ASSY from its connector CN44 on the
C362MAIN board.
7.
Remove the two screws (CBS M2x6) securing the Paper Rear Sensor, and remove it.
Paper_Rear sensor
Paper Guide U
Figure 4-167.
8.
Release the harness for the P_Rear Sensor ASSY from the cable clamps.
NOTE: When removing/installing the Paper Guide U, be careful not to mar the
P_REAR Sensor ASSY with the edge of the sensor inspection window.
NOTE: P_REAR Sensor ASSY position is adjusted at factory. Therefore, be sure
to mark its current position before removing the screws.
Disassembly & assembly

4.2.3.24 Removing the Front Cover Sensor ASSY

1.
(Without Paper Guide U)
Sensor L
Screw
Disassembly Flow
If you replace the P_REAR Sensor ASSY, perform the necessary
adjustment listed in Chapter 5.
Perform the Steps 1 to 11 in "Front Cover Removal" (Paragraph "Front Cover
Removal 130.)
Front cover sensors are built in the both hinge unit.
Front
Cover
Left hinge unit
Figure 4-168.
Revision A
Right hinge unit
183