EPSON Stylus Pro 10000/10000CF

5.2.3.9 Offset adjustment for dot missing detector

Automatically determined offset value after the dot missing detection operation. Refer to
the paragraph "Offset adjustment for dot missing detector" on page 237 for details.
Adjustment

5.2.3.10 P_Front/Rear/Edge sensor adjustment

n
Performing these adjustment, set the H top cover and front cover
preventing from outside light exposing.
n
Set the paper set lever after adjustment sheet setting.
P_FRONT/REAR SENSOR
1.
Remove the rear cover.
2.
Set the adjustment sheet normally. (Refer to Table 5-4, "Test sheet and Adjustable
VR," on page 201.)
3.
Enter the Self-diagnostic mode. (Refer to "Start-up procedure" on page 213.)
Table 5-4. Test sheet and Adjustable VR
Sensor
P_Front
P_Rear
P_Edge
*:Blight Recycle Paper (XEROX) is soled in japanese market only.
4.
Select "Test"/"Sensor"/"FrontAD" or "Test"/"Sensor"/"Rear" by panel operation.
(Refer to "Sensor" on page 217.)
5.
Adjusting each VR (Refer to "VR layout" on page 202.) corresponding to the each
sensor, the ON-OFF value (Left value) becomes within the adjustment range. (Refer to
Table 5-5, "Adjustment Range," on page 202.)
Adjustment Steps
Adjustment sheet
Rough adjustment
KIMOTO #300
VR2
Tracing Paper
KIMOTO #300
VR1
Tracing Paper
Blight Recycle Paper
VR3
(XEROX)*
Revision B
Fine adjustment
VR5
VR4
VR6
201