Maintenance Mode 2 - Epson StylusPro 10000 Service Manual

Table of Contents

Advertisement

EPSON Stylus Pro 10000/10000CF
Ink capacity : Ink capacity information
Ink remaining : Ink remaining
of each ink cartridge is displayed.
Product date : Product date information
<YY>/<MM> form.
Expire date : Ink expire date information
Ink life : Ink life information
saved in CSIC of each ink cartridge is displayed.
Passed time : Passed time after opened
Product Description
saved in CSIC of each ink cartridge is displayed.
saved in CSIC of each ink cartridge is displayed with
saved in CSIC of each ink cartridge is displayed.
of each ink cartridge is displayed.

1.8 Maintenance Mode 2

The following explanations regarding operating Panel service
functions are for service and support purposes only; do not share this
information with the user.
o
Startup
1.
The maintenance mode 2 display is selected by switching power ON while pressing the
Paper source, Cut/Eject, and Paper Feed buttons.
o
Operation
1.
The Setup items select mode is selected by pressing the Item button once. The first
Setup item on the Setup menu is displayed. The display is in the '[Item]=[current setup
value]*' format. The '*' represents the current setup value.
2.
The Setup items are displayed in the '[Item]=[current setup value]*' format in turn
each time the Item button is pressed.
3.
With the Setup items displayed, the settable values are displayed in turn in the
'[Item]=[current setup value](*)' format each time the setup value + button or setup
value - button is pressed. The '*' is only displayed when the displayed setup value is
the current value. The values are displayed in reverse order by pressing the setup value
- button. If the setup value + button or setup value - button is pressed for more than the
set period of time the setup values are displayed periodically in forward or reverse
order respectively.
4.
When the Item button is pressed, the displayed setup value is entered and recorded as
the current setup value, and any associated operations are run. No operation occurs
if'*' is already displayed.
5.
When the Item button is pressed in the Setup item select mode, the system returns to
the maintenance mode 2.
o
Termination
1.
Switch power OFF > ON.
o
Maintenance mode 2 setup items : Refer to the following table.
Maintenance Mode 2
Revision B