Perform the cleaning reliability test.
Perform the cleaning designated number.
When the reliability number is [-1], reliability is repeated until [Pause] key is input.
When the reliability number is [-1], the biggest count number is 99,999,999 times (within 8
column), and the count become 0 in the case that this is exceeded.
Following figure showing the cleaning reliability test menu sequence.
Cle. Prm. CL1
Enter
Life Count : -1
Enter
Wait Time (Sec).0
Enter
Count : 10
Enter
End : 50
Figure 5-105.
o
As for the parameter of cleaning kind, [CL1], [CL1'], and [CL2] are possible
select.
o
The maximum value of the reliability number designation is [99,999,999 times].
Adjustment
Adjustable with "Paper Feed +/-" key.
Adjustable with "Paper Feed +/-" key.
Adjustable with "Paper Feed +/-" key.
Self-Diagnostics
o
The maximum value of the wait time is [999 seconds].
o
There is the wait time that is designated whenever the cleaning reliability test ends
1 time.