EPSON Stylus Pro 10000/10000CF
*1 : Confirm that there are dot missing at the time of the nozzle checking pattern printing.
In the case that the abnormality was admitted pushing the cleaning switch for 3 seconds,
and the head cleaning (about 2 minutes : Until the printing passable lamp changes to the
inspection from the flickering) is run. The nozzle checking tries to be run once again
hereafter.
(Good example)
*2 : Use the status sheet as for the confirmation of the part life (the exchange time) that
showed in the Table 6 -2, because the status sheet prints the information that showed in the
Table 6 -3.
Maintenance
Figure 6-3.
(Bad example)
Figure 6-4.
Item
Version of the firmware
Before page ink used quantity
Printing number of sheets (C).
Printing number of sheets (M)
Printing number of sheets (LC)
Printing number of sheets (LM)
Printing number of sheets (Y)
Printing number of sheets (K)
Accumulation ink consumption
volume
Accumulation paper
consumption volume
Ink counter clear
Paper counter clear
General Maintenance Issues
Table 6-3. Status sheet
Panel display
Setting value
The firmware version of the
VERSION
TOxxxx. yyyy .zzzz
printer is displayed.
The ink used quantity in the page
INK
xx.x g
that printed in immediately
before is displayed.
Whether is displayed
PRINTABLE SHEET
additional how many sheets
PRINTABLE SHEET
of printing possibility, on the
PRINTABLE SHEET
basis of the ink used quantity
in the page that printed it in
PRINTABLE SHEET
immediately before every the
xxxxxxx sheet
PRINTABLE SHEET
ink.
C : Cyan
M : Magenta
LC : Light cyan
PAGE COUNT
LM : Light magenta
Y : Yellow
K: Black
The used quantity of the ink is
TOTAL INK
xxxxxxx.x g
displayed with "g" unit.
The length of the form that used
PAPER COUNT xxxxxxx cm
it is displayed with "cm" unit.
The ink counter is initialized in
0.
INK COUNTER
The consumption volume of the
Run
CLEAR
ink in an optional printed matter
can be instrumented with [Ink
counter] and [Ink counter clear].
The form counter is initialized in
0.
PAPER
The used quantity of the form in
COUNTER
Run
an optional printed matter can be
CLEAR
instrumented with the [form
counter] and [form counter
clear].
Revision A
Contents