Epson StylusPro 10000 Service Manual page 192

Table of Contents

Advertisement

EPSON Stylus Pro 10000/10000CF
BACKING UP PARAMETERS FROM MAIN BOARD TO MEMORY
CARD.
1.
Remove the slot cover (two screws) from the rear of the printer, and make sure the
operation panel unit is attached
2.
Insert the Memory card (top facing the outside of the printer) into the PC card slot
connector (CN20) on the Main Board, and then turn on the printer.
3.
Make sure the following message appears on the LCD.
Wait:F->M Push:M->F
4.
Press any button on the operation panel within 15 seconds. Start up the down loading
operation when the button is depressed.
Mcard -> Flash
You need to press any button on the control panel within 15 seconds;
otherwise the printer will start the backup procedure instead of the
download procedure. This overwrites parameter data stored in the
memory card with data stored in the Main Board Flash memory. In
other words, this clears the parameters!
5.
When the backup procedure is finished, the following message appears.
6.
After making sure the printer is finished, turn off the printer and remove the memory
card.
7.
Install the slot cover with two screws.
Adjustment
End [Success]
BACKUP/DOWNLOAD ERROR RECOVERY
If an error occurs during the backup or download procedure, the following message appears
on the LCD.
If you find the message above, one of the following errors has occurred. Using a different
Memory card, try the operation again.
and retry it again.
n
Flash memory/ write error
n
Flash memory/ erase error
n
Memory card/ write error
n
Memory card/ erase error
If a different memory card does not solve the problem, there is a problem with the flash
memory on the Main Board and a backup is not possible.
RANGE OF BACKED UP PARAMETERS
The following parameters on the C362 Main Board are backed up during the back up
operation.
Flash ROM addresses 000~5FF<H> (except for 120~13F<H>)
Adjustment Steps
Revision B
End [Error]
192