Removing The T Fence (Scale 180A) - Epson StylusPro 10000 Service Manual

Table of Contents

Advertisement

EPSON Stylus Pro 10000/10000CF
4.
Remove five screws (
:M4x8) securing "Ink Pump ASSY".
Screw
Figure 4-141.
5.
Disconnect the six tubes from the air distributor.
1
2
3
4
5
6
Figure 4-142. Air tube location
Disassembly & assembly
Screw
Air distributor
6
5
4
3
2
1

4.2.3.16 Removing the T Fence (Scale 180a)

1.
Remove the R Side Cover as described in "R Side Cover Removal 124.
2.
Remove the L Side Cover as described in "L Side Cover Removal 124.
3.
Remove the H Top cover as described in "H Top Cover Removal 123.
4.
Marking 7 place of the T fence hold position.
5.
Loosen two revolution 7 place of the T fence hold, then lift up it and fixed.
T fence hold
Screw
6.
Remove the left side of tention spring.
Spring
Disassembly Flow
Figure 4-143.
T fence
Figure 4-144.
Revision A