Cutter Pressure Adjustment - Epson StylusPro 10000 Service Manual

Table of Contents

Advertisement

EPSON Stylus Pro 10000/10000CF

5.2.3.12 Cutter Pressure Adjustment

This adjustment is needed in case of C362DRV board replacement, Carriage unit
replacement, Sub platen unit replacement and Shutter unit. If the paper cutter operation will
not be performed correct, you may adjust it.
<Required tool>
o
Tension Gauge
<Adjustment procedure>
1.
Select the "Check: Adjustment" from the diagnostic mode and push Enter switch, then
release the capping.
2.
Select "Adj.: Cutter" and press Enter switch to enter the cutter pressure adjustment.
3.
Press Enter switch in several times until "Pressure=35%" will be appeared on the LCD.
4.
Move the carriage unit to the center of most right sub platen.
5.
Connect the string between cutter and hook of the tension gauge.
String
Paper cutter
Figure 5-15. Cutter Pressure Adjustment
Adjustment
6.
7.
8.
9.
Tension Gauge
Cutter solenoid
Adjustment Steps
When "Exec. Adj.?" will be displayed on the LCD, press Enter switch, the cutter will
be move to downward. At the time, measure the cutter pressure.
Pressing Paper feed +/- switches, adjust the pressure to be within 350 and 700gf.
Press Enter switch, the cutter move to upward.
Move the carriage to the center and most left sub platen, repeat from Step 6 to 8.
Figure 5-16. Adjustment positions
Revision B
Sub platens
206

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents