Avaya ESS User Manual page 95

Enterprise survivable servers
Table of Contents

Advertisement

Table 10: Installing ESS with existing servers (continued)
Task
3a. ESS with CSS-Port
Network Connectivity
(PNC)
3b. ESS with Direct-PNC
3c. ESS with ATM-PNC
3d. ESS with IP-PNC
4. ESS with mixed Port
Network Connectivity
(PNC)
Information
Install an IP Media
Processor and an IPSI
board in every survivable
Port Network.
In all IPSI controlled Port
Networks, verify that the
TN570D board is used.
ESS is not supported in a
Direct Connect
environment. The Direct
Connect environment must
be converted to an IP
Connect environment.
All ATM PNC and CES
boards must be TN2306B
boards.
If the ATM is local to the
Port Networks, a five to one
IPSI port ratio is allowed for
each survivable Port
Network.
If the ATM is remote to the
Port Networks, an IPSI is
required in each survivable
Port Network.
No changes are needed for
an IP Connect
environment.
Install an IP Media
Processor and an IPSI
board in every survivable
Port Network.
ESS Installation Checklist
Documentation
For instructions on how to install
an IP Media Processor, an IPSI
board, or a TN570D board see:
Adding New Hardware - Avaya
S8500 and S8700 Media Servers
(555-245-112).
To convert a Direct Connect
system to an IP Connect system
see:
Upgrading, Migrating, and
Converting Media Servers and
Gateways (03-300412).
To change a TN board see:
Adding New Hardware - Avaya
S8500 and S8700 Media Servers
(555-245-112).
For instructions on how to
convert to a mixed PNC
environment see:
Upgrading, Migrating, and
Converting Media Servers and
Gateways (03-300412).
Issue 1.1 June 2005
2 of 10