5-8
Chapter 5 - HOTEL/MOTEL -- Operator Features
Also, one beep will be provided and the LCD will stay for 3 seconds before going back
to normal operation.
Check Out
1. Press [FEAT ] + [7] + [#] + [3]. The display shows:
2. Enter the desired station number and press [save].
If the station directory number is valid, all the DSS/BLF of that station will be green
slow flash, the COS of that station will be reduced to 7 and the Room Status will be
Check-out. Also, one beep will be provided and the LCD will stay for 3 seconds before
going back to normal operation.
Room Ready
When the Station Type database is sent from RMP to KSU, if the Station Type for particular
stations is GUEST and those stations are not in Check-in, Check-out, Maintenance, or
Unavailable room status, all the DSS/BLF of those stations will be dark, the COS of those
stations will be 7 and the Room Status will be Room Ready.
1. Press [FEAT ] + [7] + [#] + [1]. The display shows
2. Enter the Station Directory number + [save].
A double beep is heard when:
Maid Clean Code
When the Room Status of a station is Check-out, it can be changed to Room Ready by
pressing the access code [FEAT] + [7] + [#] + [1] at that station. When the Room Status
is changed successfully, a beep will be provided for Digital Keyset or a confirmation
C HE CK IN
3 0 1
C HE CK OU T
bk sp s ave
C HE CK OU T
3 0 1
R OOM R EA DY : _
bk sp s ave
Station number entered is unavailable.
Station Type does not = GUEST.
The tenant of the station is not the same as the Tenant Attendant operating this
function.
The station is not at Check-out, Maintenance, or Unavailable Room Status.
: