39
Clearing sFlow statistics
TABLE 170
This field...
Port Sampling Rates
Hardware Sample Rate
Displaying sFlow counters
sFlow counters are included in the output of the show interface ethernet command.
BigIron RX(config)# show interface ethernet 1/1
GigabitEthernet2/1 is disabled, line protocol is down, link keepalive is
enabled
Hardware is GigabitEthernet, address is 000c.dbe2.5900 (bia 000c.dbe2.5900)
Configured speed 1Gbit, actual unknown, configured duplex fdx, actual unknown
Configured mdi mode AUTO, actual unknown
Member of 2 L2 VLANs, port is tagged, port state is Disabled
STP configured to ON, Priority is level7, flow control enabled
Force-DSCP disabled
mirror disabled, monitor disabled
Not member of any active trunks
Not member of any configured trunks
No port name
MTU 1522 bytes, encapsulation ethernet
300 second input rate: 0 bits/sec, 0 packets/sec, 0.00% utilization
300 second output rate: 0 bits/sec, 0 packets/sec, 0.00% utilization
0 packets input, 0 bytes, 0 no buffer
Received 0 broadcasts, 0 multicasts, 0 unicasts
0 input errors, 0 CRC, 0 frame, 0 ignored
0 runts, 0 giants, DMA received 0 packets
0 packets output, 0 bytes, 0 underruns
Transmitted 0 broadcasts, 0 multicasts, 0 unicasts
0 output errors, 0 collisions, DMA transmitted 0 packets
In the output, the sFlow counters show:
•
•
•
Syntax: show interface ethernet
Clearing sFlow statistics
To clear the UDP packet and sFlow sample counters in the show sflow display, enter the following
command.
BigIron RX(config)# clear statistics.
Syntax: clear statistics
This command clears the values in the following fields of the show sflow display:
•
1048
sFlow information (Continued)
ignored - Bad Ethernet frames were received which includes CRC, runts, giants, and malformed
frames
DMA received - Good packets were received
DMA transmitted - Good packets were transmitted
UDP packets exported
Displays...
The sampling rates of a port on which sFlow is enabled.
The actual sampling rate. This is the same as the Global Sample Rate
BigIron RX Series Configuration Guide
53-1002253-01