Management Access On S-Series Stacks - Dell Force10 C150 Configuration Manual

Ftos configuration guide ftos 8.4.2.7 e-series terascale, c-series, s-series (s50/s25)
Hide thumbs Also See for Force10 C150:
Table of Contents

Advertisement

Figure 50-6. Adding a Standalone with a Lower MAC Address but Higher Priority to a Stack—After
-------------------------------STANDALONE AFTER CONNECTION----------------------------------
Standalone#00:18:27: %STKUNIT2-M:CP %CHMGR-5-STACKUNITDETECTED: Stack unit 0 present
00:18:27: %STKUNIT2-M:CP %CHMGR-5-STACKUNITDETECTED: Stack unit 1 present
00:18:40: %STKUNIT2-M:CP %CHMGR-2-STACKUNIT_DOWN: Stack unit 0 down - card removed
00:18:40: %STKUNIT2-M:CP %CHMGR-2-STACKUNIT_DOWN: Stack unit 1 down - card removed
00:19:30: %STKUNIT2-M:CP %POLLMGR-2-ALT_STACK_UNIT_STATE: Alternate Stack-unit i
s present
00:19:30: %STKUNIT2-M:CP %CHMGR-5-STACKUNITDETECTED: Stack unit 0 present
00:19:30: %STKUNIT2-M:CP %CHMGR-5-STACKUNITDETECTED: Stack unit 1 present
[remaining bootup messages omitted]
------------------------------------STACK AFTER CONNECTION----------------------------------
Stack#3w1d15h: %STKUNIT1-M:CP %POLLMGR-2-ALT_STACK_UNIT_STATE: Alternate Stack-unit is not
present
3w1d15h: %STKUNIT1-M:CP %CHMGR-5-STACKUNITDETECTED: Stack unit 2 present
Going for reboot. Reason is Stack merge
3w1d15h: %STKUNIT1-M:CP %CHMGR-2-STACK_UNIT_DOWN: Stack-unit 0 down - card removed
[bootup messages omitted]
Stack#show system brief
Stack MAC : 00:01:e8:d5:ef:81
--
Stack Info
--
Unit
UnitType
Status
---------------------------------------------------------------------------
0
Member
online
1
Standby
online
2
Management
online
3
Member
not present
4
Member
not present
5
Member
not present
6
Member
not present
7
Member
not present

Management Access on S-Series Stacks

You can access the stack via the console port or VTY line.
Console access: You may access the stack through the console port of the stack manager only. Like a
standby RPM, the console port of the standby unit does not provide management capability; only a
limited number of commands are available. Member units provide a severely limited set of commands,
as shown in
Figure
50-7.
Remote access: You may access the stack with SNMP, SSH, or Telnet through any enabled, Layer 3
interface on any stack unit. There is no dedicated management port or management route table.
ReqTyp
CurTyp
S50V
S50V
S50N
S50N
S50V
S50V
Version
Ports
7.8.1.0
52
7.8.1.0
52
7.8.1.0
52
Stacking S-Series Switches | 1025

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents